Skip links

Safety Testing Laboratory

The laboratory adheres to the quality policy of “fairness, science, accuracy and efficiency”, has advanced and perfect testing equipment and experienced technical personnel, and has established a good cooperative relationship with international authoritative certification bodies. Help enterprises solve various safety problems encountered in the process of product design and development, including testing and certification and other technical links, and assist enterprises to apply for and obtain UL, CE, GS, CB, SAA, PSE, KC, CCC, CSA, FOA, SONCAP, SABS, SASO and other product safety certifications. Provide high-quality and fast services for the safety and reliability of customers’ products, as well as environmental protection and cost control.

Obedience Scope of business

1. Assist customers to eliminate potential safety hazards in the product design stage, such as electrical clearance, creepage distance, safety isolation, etc., evaluate the structural design, and avoid the loss of mold modification.

2. Conduct electrical testing and structural evaluation in the early stage of product certification, and provide audit reports.

3. Assist customers to communicate with the certification body and execute the application document operations, which can save application time and reduce the trouble of customers in the certification application process.

4. Assist customers to deal with problems arising from factory review and guide customers on related matters of factory review.

5. Assist enterprises in SAFETY personnel training/consulting on SAFETY regulations and standards in various countries/laboratory space rental.

6. We can assist customers to complete the following certification test projects:

欧洲:CE-LVD、GS、TUV-mark、EMF、KEMA、NEMKO 、SEMKO、DEMKO、ENEC、BEAB、GOST、ERP

Asia: CCC, CQC, KC, PSE, BSMI, PSB, SASO

North and South America: UL/cUL, FDA, ETL/cETL, CEC, CTUVus, CSA/CSAus, NOM, IRAM, DOE, UC

Australia and Africa: SAA, MEPS, SONCAP, SABS, IEC

Global certification mark: CB

Safety Testing Laboratory
Test items

Input Test Label Durability Test Capacitive Discharge Test Current Limit Circuit Test

Power limit test Impedance to protect grounding Tidal test Creepage distance and electrical clearance

Working voltage Power line tension test Steady running test 250N steady running force test

Steel ball impact test Drop test Stress reduction test Load test

In-line equipment torque test, temperature rise test, contact current test, electrical strength test

Abnormal Tests Heat and Milk Resistance Ball Pressure Tests Radiation, Toxicity and Similar Hazards

Detection range

Audio/video/information technology and communication technology equipment: IEC/EN IEC 62368-1, AS/NZS 62368.1, 162368-1, CAS 62368-1, UL 62368-1, 68 4943.1

电源类:IEC/EN/UL60950-1,IEC/EN/UL60065,EC/EN/UL60601,EC/EN60335-2-29,IEC/EN61558-1/-2,AS/NZS 61558.1/.2.x, UL1310,UL1012,UL 697,GB19510,GB8898,GB4943

Uninterruptible Power Supply (UPS) : IEC/EN 62040-1-1, A5 62040.1.1, UL1778, Class 2 and Class 3 transformers, UL 1310, UL 62368-1

Batteries : UL 2054,UL 1642,IEC/EN 62133,UN 38.3

Lamps : IEC/EN 60598-1/-2-X,AS/NZS 60598.1/.2.X,J60598-1/-2-X,K60598-1/-2-X,GB 7000.1/.X

Stationary luminaires : UL I598,IEC/EN 60598-2-1,GB 7000.201

Recessed luminaires : UL I598,IEC/EN 60598-2-2,GB 7000.202

Portable light fixtures : UL I53,IEC/EN 60598-2-4,GB 7000.204

Tunnel lights/street lights : UL I598,IEC/EN 60598-2-3,GB 7000.5

Emergency lighting fixtures : UL 924,IEC/EN 60598-2-22,GB 7000.2

Floodlight fixtures : ULI598,IEC/EN60598-2-5,GB7000.7

Track lights : UL 1574,UL I598,IEC/EN 60598-2-1,GB 7000.201

General lighting self-ballast lamps (energy-saving lamps, spotlights, LED bulb lights) : UL I993,IEC/EN 60968,AS/NZS 60968,IEC/EN 62031,IEC/EN 62560,IEC 62471

LED tubes : UL 8750,UL 1993,UL 1598C,IEC 60061,IEC 62471,IEC 62031,IEC 61347-2-13 ,IEC61195,IEC 61199

The control device of the lamp: electronic ballast : IEC/EN 61347-1/-2-X,AS/NZS 61347.1/.2.X,UL 8750,UL 935,GB 19510.X

LED modules with AC or DC electronic controls : IEC/EN 61347-2-13,GB 19510.14

AC electronic ballast for yellow lights : IEC/EN61347-2-3,G8 19510.4

British light ballast : IEC/EN 6I347-2-8,GB 19510.9

Discharge lamp (except incineration lamp) ballast : IEC/EN 61347-2-9GB 19510.10

Luminaire EMF : EN 62493:2010

Household appliances: A5/NZ560335.1/.2.X, J60335-1/2-X, K60335-1/2-XGB4706.1/ X

Motor Food Processors (Blenders/Juicers/Meat Grinders/Slicers) : UL982,IEC/EN60335-2-14,GB4706.30

Liquid Heater County (Coffee Maker/Electric Kettle) : ULI082,IEC/EN60335-2-15,GB4706.19

Skin or hair care appliances (hair dryers/curling irons/straighteners, etc.) : UL859,IEC/EN60335-2-23,GB4706.15

Battery charger : UL1310,IEC/EN60335-2-29,GB4706.18

Room electric heater : UL1278,IEC/EN60335-2-30,GB4706.23

Induction cooktop : IEC/EN60335-2-9,GB4706.29

Massager : UL1647,IEC/EN 60335-2-32,GB4706.10

Air purifier/negative ion generator : UL867,IEC/EN60335-2-65,GB4706.45

Hot and cold water dispensers : IEC/EN60335-2-15,GB4706.42

Humidifier : UL998,IEC/EN 60335-2-98

Electric iron : UL1005,IEC/EN60335-2-3,GB 4706.2

Shavers, hair clippers and similar appliances grills, ovens, toasters and fryers, electric frying pans : UL 1028,IEC/EN 60335-2-8 UL 1026,IEC/EN 60335-2-9,GB 4706.14

Fan : UL507,IEC/EN 60335-2-80,G8 4706.27

High temperature : IEC 60068-2-2(GB2423.2): Dry heat

Alternating damp heat (12+12 hour cycle) : IEC 60068-2-30(GB2423.4):Damp heat, cyclic (12 h +12 h cycle)

Lamps : LM-79,LM-80, CEC-400-2010-0 12, Fixtures Eligibility Criteria-Version 4.2, AS/NZS 4782,4783, 4934,4879,IEC 859/2009

Power supply : IEC-400-2010-012,IEC 278/2009,AS/NZS 4665,6820943

Audio and video category : Version 5.3 (Television), Version 4.0(Set-top Boxes), AS/NZS 62087(Set Top Boxes, Television),IEC/642:2009

We can provide technical services such as mapping testing and certification for enterprise products. Solve the relevant technical problems of enterprises after product design, ensure that they meet the corresponding electromagnetic compatibility standards, and obtain certification as soon as possible.

Engineers have many years of experience in EMC, safety regulations and lightning protection countermeasures in professional laboratories, and are familiar with the increased device costs in the countermeasure process, and can provide fast, efficient and low-cost rectification suggestions for enterprise products in a short period of time, so that the cost of mass production is low and the interests of customers are improved.